Simulation Data Inspector (SDI) does not show signals marked for streaming from Simulink model running on Speedgoat
24 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
MathWorks Support Team
el 12 de Feb. de 2019
Editada: MathWorks Support Team
el 14 de Mzo. de 2025
I marked some signals for logging and ran my model in External Mode ("Run on target") on a Speedgoat Simulink Real-Time target. Everything appears to work correctly except that there are no signals shown in SDI during the simulation.
Respuesta aceptada
MathWorks Support Team
el 14 de Mzo. de 2025
Editada: MathWorks Support Team
el 14 de Mzo. de 2025
1) Make sure that the Simulink Data Inspector is working as expected by running the example below which does not use Simulink Real-Time.
2) Try the shipped example of logging signal in SDI for real-time models:
3) Check the MATLAB Command Window for warnings about non-observable signals when you are running your own model. See the following post for details:
https://www.mathworks.com/matlabcentral/answers/773802-why-am-i-unable-to-log-or-stream-signals-when-my-application-is-running-on-hardware-external-mode-a
4) If the above steps are all good except signal logging in SDI, revise the firewall and antivirus settings on your development computer:
0 comentarios
Más respuestas (0)
Ver también
Categorías
Más información sobre Real-Time Signal Logging and Streaming en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!