'referenced model not connected to external simulation' in Simulink real time
1 visualización (últimos 30 días)
Mostrar comentarios más antiguos
I'm using a model that contains a referenced model included from a git submodule.
I'm trying to build the model with simulink real time and access parameters with the External mode.
Signals entering the referenced model don't exit the model and I can't see signals in the referenced model.(All signals are 0 on displays)
Even signals initialised in the referenced model don't exit the referenced model and get shown as 0 outside of the referenced model.
When entering the referenced model in External mode I can see the warning 'referenced model not connected to external simulation' in the bottom left corner.
How can I fix this issue?
0 comentarios
Respuestas (1)
Jonas
el 21 de Jun. de 2019
It is impossible to enter External Mode for referenced models. If you want to monitor or log signals, you need to bring them out of the referenced model as a signal Outport. This can be a bus for your convenience. If you want to change parameters inside the referenced model, you can create a Simulink Parameter and check the 'Argument' option. The parameter is now adaptable from outside of the referenced model with for example set_param.
Ver también
Categorías
Más información sobre Test Model Components en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!