Plot for specific vibrational heat

1 visualización (últimos 30 días)
Mohsen Nashel
Mohsen Nashel el 16 de Sept. de 2019
Editada: madhan ravi el 16 de Sept. de 2019
Hello! I'm trying to plot the outputs of cv for the formula given in the picture to the range of temperatures between 300 to 3000. But it still gives me error due to the matrix size doesn't match.
dT=100;
T=300:dT:3000;
theta_v=3400;
R=287;
C_vv=((R*theta_v^2*(exp(theta_v/T)))/(((exp(theta_v/T))-1)^2*T^2));
figure(1)
plot(T, C_vv)
grid
xlabel('Temperature')
ylabel('Cv')
title('Vibrational Specific Heat vs Temperature for Nitrogent')

Respuesta aceptada

Star Strider
Star Strider el 16 de Sept. de 2019
Use element-wise operations:
C_vv=((R*theta_v^2*(exp(theta_v./T)))./(((exp(theta_v./T))-1).^2.*T.^2));