HDL Coder Filter Latency

1 visualización (últimos 30 días)
Ewan Mackenzie
Ewan Mackenzie el 23 de Mzo. de 2020
Comentada: Ewan Mackenzie el 27 de Mzo. de 2020
Hi
Ive complied a fully paralell FIR filter using the FilterDesigner and HDL Coder and it reported the latency as 2. I am struggling to understand what the latency is exactly, is it the number of clocks required for a valid output? - 1 clock for multiplication and another for summing, but if so would the delay pipeline not also require a clock cycle?
-- -------------------------------
-- Filter Structure : Direct-Form FIR
-- Filter Length : 65
-- Stable : Yes
-- Linear Phase : Yes (Type 1)
-- Arithmetic : fixed
-- Numerator : s16,15 -> [-1 1)
-- Input : s16,15 -> [-1 1)
-- Filter Internals : Full Precision
-- Output : s33,30 -> [-4 4) (auto determined)
-- Product : s31,30 -> [-1 1) (auto determined)
-- Accumulator : s33,30 -> [-4 4) (auto determined)
-- Round Mode : No rounding
-- Overflow Mode : No overflow
-- -------------------------------------------------------------
Thanks in advance.

Respuesta aceptada

Aman Vyas
Aman Vyas el 27 de Mzo. de 2020
Hi,
Latency is defined as the total number of clock cycles required in obtaining the output.
It will depend which path are you seeing for delay pipeline. If the path you are seeing for output that will require 2 cycles.
For more information read the following article:
Hope this helps !
  1 comentario
Ewan Mackenzie
Ewan Mackenzie el 27 de Mzo. de 2020
Exactly what I was looking for, thank you

Iniciar sesión para comentar.