Problems with generating closed loop bode plot for a dc-dc converter

6 visualizaciones (últimos 30 días)
shardul adkar
shardul adkar el 10 de Jun. de 2020
Respondida: Vasco Lenzi el 2 de Jul. de 2020
Hi,
I want to generate a closed loop bode plot for a dc-dc buck converter but having issues with it. I am able to successfully generate the open loop bode plot of input to output as well as the bode plot of the compensator. However, when I am trying to generate closed loop bode plot, it is giving me a blank plot.
(Note: I am using simscape electrical and have a PWM block in my dc-dc converter)
Any help would be appreciated.
Thanks,
Shardul

Respuestas (1)

Vasco Lenzi
Vasco Lenzi el 2 de Jul. de 2020
Hi Shardul
What workflow are you using to generate the open-liip response?
I would take a look at the Frequency Estimator Block (it requires R2019a and Simulink Control Design)
In this example we show how to use it with System Identification to generate a frequency plot for the closed loop system:
This should do the trick even for a DCDC converter which cannot be linearized because of the switching nature of the PWM.
Hope this helps
Vasco

Categorías

Más información sobre Get Started with Control System Toolbox en Help Center y File Exchange.

Productos


Versión

R2020a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by