Why Do Some Blocks in the Discrecte Library Not Have a Sample Time Parameter?
Mostrar comentarios más antiguos
The doc page "Blocks for Which Sample Time is Not Recommended" has a section "Appropriate Bocks for the Sample Time Parameter" that says "Specify sample time ... in blocks designed to model rate transtions. Examples include: .... Blocks in the Discrete Library"
However, not all blocks in the Discrete Library have a Sample Time parameter, such as Difference, Transfer Fcn First Order, and Transfer Fcn Lead or Lag,
Why do those blocks not have a Sample Time parameter like the others?
Respuestas (1)
Jonas
el 16 de Jun. de 2020
0 votos
The discrete blocks you mention inherit their sample time from the blocks they are connected to. The Difference block for example, uses the current sample and the previous sample, but the sample rate is inherited by other blocks.
2 comentarios
Paul
el 16 de Jun. de 2020
Jonas
el 16 de Jun. de 2020
I do not know the reason why in some blocks you can specify the sampling time and in others it is implicit. If you want to specify a sampling time just for one block where it is implicit, you can use the Rate Transition block before and after. So it is not really a limitation, just a matter of convenience.
Categorías
Más información sobre Simulink en Centro de ayuda y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!