configure clock in simulink to inherit the sample time

4 visualizaciones (últimos 30 días)
aparnasri sekar
aparnasri sekar el 13 de Jul. de 2020
Respondida: rubindan el 13 de Jul. de 2020
I am trying to use the clock block inside a subsystem which has a function call generator, this results in the error 'clock has sample time [0, 0]. Only constant (inf) or inherited (-1) sample times are allowed in function call subsystem'. How to get rid of this?

Respuesta aceptada

rubindan
rubindan el 13 de Jul. de 2020
To get arround it you can put the clock block outside this subsystem and creatre an additional input for the clock time.

Más respuestas (0)