Cannot compute Riccati solution for LQI controller

111 visualizaciones (últimos 30 días)
Leonardo Costa
Leonardo Costa el 7 de Abr. de 2021
Comentada: Leonardo Costa el 8 de Abr. de 2021
Hi to everybody!
This is my code right now:
u=0.5;
v=0;
omega=0;
m=50;
psi=0;
c_d_Long=0.5;
c_dr=0.6;
c_d_Lat=1;
rho=1000;
L=1.2;
W=0.275;
H=0.416;
I=38;
A =[0, 0, - v*cos(psi) - u*sin(psi), cos(psi), -sin(psi), 0;
0, 0, u*cos(psi) - v*sin(psi), sin(psi), cos(psi), 0;
0, 0, 0, 0, 0, 1;
0, 0, 0, -((3*W*c_d_Long*rho*u^2*1)/10 + (3*W*c_d_Long*rho*u*sign(u))/10)/m, omega, v;
0, 0, 0, -omega, -((3*L*c_d_Lat*rho*v^2*1)/10 + (3*L*c_d_Lat*rho*v*sign(v))/10)/m, -u;
0, 0, 0, 0, 0, - (300*L*c_dr*omega^2*rho*1)/38347 - (300*L*c_dr*omega*rho*sign(omega))/38347];
B =[ 0, 0, 0, 0, 0, 0, 0, 0;
0, 0, 0, 0, 0, 0, 0, 0;
0, 0, 0, 0, 0, 0, 0, 0;
1/m, 1/m, 1/m, 1/m, 0, 0, 0, 0;
0, 0, 0, 0, 1/m, 1/m, 1/m, 1/m;
825/76694, -825/76694, 825/76694, -825/76694, 325/38347, 325/38347, -325/38347, -325/38347];
C=[1 0 0 0 0 0;
0 1 0 0 0 0;
0 0 1 0 0 0;
0 0 0 1 0 0;
0 0 0 0 0 0;
0 0 0 0 0 1];
SYS=ss(A,B,C,0);
Co = ctrb(SYS);
C=rank(Co);
Ob=obsv(SYS);
O=rank(Ob);
Q=eye(12);
R=eye(8);
klqi=lqi(SYS,Q,R)
As you can see I have a 6-dimension state with 8 input and 6 output. When i Run this code i have the following error:
Cannot compute a stabilizing LQR gain (the Riccati solution S and gain matrix K are infinite).
This could be because:
* A has unstable modes that are not controllable through B,
* Q,R,N values are too large,
* [Q N;N' R] is indefinite,
* The E matrix in the state equation is singular.
I had the same issue in the past but every time the problem was the controllabilty of the state but in this case I haven't this problem (rank of the controllabilty matrix= 6)
Hope somebody can help me.
Thank you in advance.

Respuesta aceptada

Paul
Paul el 8 de Abr. de 2021
Editada: Paul el 8 de Abr. de 2021
I'm not sure it's relevant, but should the fifth row of SYS.c be all zeros?
I suspect the issue is with stabilizability of the augmented system. Note that the code as posted is checking controllability of the plant, but the LQR solution requires stabilizability of the augmented plant, i.e., the plant combined with the integral control. I think the augmented system (not incuding the reference input) can be formed as
sysaugmented = series(SYS,ss(zeros(6),eye(6),eye(6),0)); % with SYS.c = eye(6)
Then the rank of the controllability matrix is
>> rank(ctrb(sysaugmented))
ans =
9
So the augmented system is not controllable. The eigenvalues are:
>> eig(sysaugmented)
ans =
0
0
0
0
0
0
0
0
0
-0.6188
0
0
So at least two of the uncontrollable modes are on the imaginary axis, which (I think) means the augmented system is not stabilizable, which violates one of the conditions for the solution to exist as stated here:
doc lqi
  3 comentarios
Paul
Paul el 8 de Abr. de 2021
Editada: Paul el 8 de Abr. de 2021
Yes, you can augment the plant manually with the integrator and then use the lqr() command to compute the feedback gains,subject to the standard consraints for LQR solutions.
Leonardo Costa
Leonardo Costa el 8 de Abr. de 2021
Thank you very much!