Ideal Rotational Motion Sensor (Simscape) Shows incorrect Motor Speed readings

3 visualizaciones (últimos 30 días)
Dear Matlab Community,
as shown in the attached screenshot,
the readings of motor speed and the real speed is different.
deg, deg/s are chosen for the ideal rotational motion sensor and PS-Simulink Converter
unit of Speed here is Hz, and PID Speed setpoint is around 12.5Hz,
so that I expect to see 360° jump in Angular Postion for each 80ms,
but the time period is around 40ms,..
I tried to use derivative block to calculate the angular velocity from d/dt, but the result is even more weird.
Why is that??

Respuesta aceptada

Sabin
Sabin el 31 de En. de 2023
I was not able to reproduce this problem in R2017b and newer releases. It would be helpful to provide a model and MATLAB release used when running into this problem.

Más respuestas (0)