How to setup buff block in trigger subsystem
17 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
trigger block parameters: Trigger type:function-call Sample time type:triggered
buffer block parameters: Output buffer size (per channel):256 Buffer overlap:156
err "All sample times for 'untitled/Trigger Subsystem/Buffer' must be discrete. No continuous or constant sample times are allowed"
if trigger block parameters: Trigger type:function-call Sample time type:periodic
buffer block parameters: Output buffer size (per channel):256 Buffer overlap:156
err "Port-based sample time block 'untitled/Trigger Subsystem/Buffer' has a sample time, 100, on output port 1 that does not align with the periodic sample time of function-call subsystem 'untitled/Trigger Subsystem'. Only constant (inf), inherited (-1), or periodic (1) sample times are allowed in the subsystem."
thanks
Only one buffer block in trigger subsystem Ver: MATLAB 7.11 (R2010b) Simulink 7.6 (R2010b)
3 comentarios
Respuestas (1)
Kaustubha Govind
el 16 de Jun. de 2011
The Buffer block has port-based sample times, which are not supported inside triggered subsystems. You may need to create your own S-function that imitates the functionality of the Buffer block, while reconciling its operation within triggered subsystems.