5 phase park transform

117 visualizaciones (últimos 30 días)
Balazs Salamon
Balazs Salamon el 15 de Jul. de 2021
Respondida: Sabin el 2 de Jul. de 2025
Hello,
I would like to understand the park transformation block for a 5 phase system (abcde to dq0). The output vector contain an x and y component. Can anyone explain what tehse components mean physically or why are they their? I have written some code which does the calculation but I got the same values for both x and y. Can anyone link me some literature on this?
Thank you in advance!

Respuestas (1)

Sabin
Sabin el 2 de Jul. de 2025
Park transform for five phases is an extension from a three-phase machine. It converts the phase quantities of the stator into direct and quadrature components. The three additional quantities (namely x, y, and 0) do not contribute to a vector that has any spatial relationship with the rotor field. These are zero-sequence components.

Categorías

Más información sobre Control en Help Center y File Exchange.

Productos


Versión

R2021a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!