DICOM tag with missing VR loads inconsistently (Philips ScaleSlope)
5 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Bogdan Dzyubak
el 15 de Jul. de 2021
Editada: Bogdan Dzyubak
el 15 de Jul. de 2021
I have two Philips mDixon datasets. In both, the VR for ScaleSlope is apparently missing:
(2005,100D) 00 A0 AA 44 # 1, 4
This should be read as a single value. In fact, dcminfo reads it correctly in one case: ScaleSlope = 1365, and incorrectly in the other: ScaleSlope = 0
160
170
68
Both times, I am using the same dictionary with the tag filled in (2005,100d) FL ScaleSlope 1.
1) What might cause one case to read correctly and the other not?
2) Is it possible to convert the string of 4 int8 numbers to a single 'single data type' number?
Many thanks,
Bogdan
0 comentarios
Respuesta aceptada
Walter Roberson
el 15 de Jul. de 2021
A = uint8(sscanf('00 A0 AA 44', '%2x'))
typecast(A, 'single')
(Thank you for mentioning your release -- that saved me from showing you code that would not work in your release)
1 comentario
Más respuestas (0)