Does the "Load Impedance" field in the "Output Port" block accept complex numbers in RF Blockset 2.3 (R2008b)?

1 visualización (últimos 30 días)
I would like to know if the "Load Impedance" field in the "Output Port" block (from the RF blockset library) can accept a complex number (that is, capacitive output (real and imaginary number)). The reason for this question is because I want to use the following configuration: Input Port -> General Passive Network -> Output Port wherein Terminating load impedance: ZL = 2 kΩ 3 pF
The Help Documentation for Transmission Line, S-Parameters Passive Network, S-Parameters Amplifier and S-Parameters Mixer blocks explicitly mention that complex impedances are allowed. This is not the case for the "Output Port" block.

Respuesta aceptada

MathWorks Support Team
MathWorks Support Team el 27 de Jun. de 2009
The "Load Impedance" of the "Output Port" block does accept a complex number.