Bypassing the internal (Linear) observer in MPC toolbox 3

2 visualizaciones (últimos 30 días)
Qadeer Ahmed
Qadeer Ahmed el 16 de Jun. de 2011
Editada: Bill Tubbs el 24 de Mayo de 2021
I wish to use my designed non-linear Observer with the MPC block (MPC toolbox v3.1)for the real-time control of a system. However, the MPC block contains its own linear observer for state estimation.
How can I bypass (disable) the internal linear observer of the MPC block in Simulink for real-time implementation.

Respuestas (1)

Bill Tubbs
Bill Tubbs el 24 de Mayo de 2021
Editada: Bill Tubbs el 24 de Mayo de 2021
Might be 10 years too late but I had this question and it looks like you can set the following check box below in the Simulink MPC block parameters:
When I did this, the usual 'measured output' inport is replaced with an inport labelled `x[k|k]` for the state estimates from some other observer.
[I'm using MATLAB 2019b.]

Categorías

Más información sobre Explicit MPC Design en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by