Respondida
why doesn't my hard stop in Double-Acting Actuator (IL-G) work?
The answer is the stiffness of the stop was too small. The default value of stiffness 1e6 was allowing the piston to keep movin...

casi 5 años hace | 0

| aceptada

Pregunta


why doesn't my hard stop in Double-Acting Actuator (IL-G) work?
I am using a Linear actuator with piston motion controlled by opposing hydraulic and gas chamber, which allows the setting of t...

casi 5 años hace | 1 respuesta | 0

1

respuesta