Pregunta


Power operator (^) precedence levels and evaluation order
While 2^-1^-2 returns 4, which indicates a "left to right" evaluation order (as it is common in many programming languages), ...

5 meses hace | 1 respuesta | 2

1

respuesta

Pregunta


Enabled Subsystem does not reliably disable
The Simulink model shown in the screenshot does not behave as I expect, and I would like to understand the reason. All blocks...

8 meses hace | 1 respuesta | 1

1

respuesta

Resuelto


Remove the polynomials that have positive real elements of their roots.
The characteristic equation for a dynamic system is a polynomial whose roots indicate its behavior. If any of the roots of the p...

más de 2 años hace

Resuelto


Summing digits
Given n, find the sum of the digits that make up 2^n. Example: Input n = 7 Output b = 11 since 2^7 = 128, and 1 + ...

más de 2 años hace

Resuelto


Finding Perfect Squares
Given a vector of numbers, return true if one of the numbers is a square of one of the numbers. Otherwise return false. Example...

más de 2 años hace

Resuelto


Interpolator
You have a two vectors, a and b. They are monotonic and the same length. Given a value, va, where va is between a(1) and a(end...

más de 2 años hace

Resuelto


Times 2 - START HERE
Try out this test problem first. Given the variable x as your input, multiply it by two and put the result in y. Examples:...

más de 2 años hace

Pregunta


Rank of symbolic matrix is wrong (but too small, not too large)
I get a wrong result using the sym/rank command. I'm aware of the limitations of this command as it does not simplify expression...

más de 3 años hace | 1 respuesta | 1

1

respuesta

Pregunta


Simulation runs fine despite error (index out of bounds)
Hello. Summary For my simple model, Simulink (R2020b) throws an error during Model Update, but afterwards allows me to simulat...

casi 4 años hace | 1 respuesta | 1

1

respuesta

Respondida
Number of necessary time steps to handle a Zero-Crossing?
First of all: Thank you for your efforts! Your guesses are similar to my guesses. ;-) I've been aware of the fact that my minim...

más de 4 años hace | 0

Pregunta


Number of necessary time steps to handle a Zero-Crossing?
Over the years I have observed that Simulink usually uses 3 time steps to handle a zero-crossing, but in some cases it uses only...

más de 4 años hace | 2 respuestas | 0

2

respuestas

Respondida
What do TzL & TzR mean in Simulink Debugger ?
I've seen these when debugging zero-crossings. So "z" might mean "zero-crossing", "L" and "R" might be "left" (before) and "righ...

más de 4 años hace | 0

Pregunta


Integrator State Port: Why is its use restricted?
Hello. I'd like to know why the use of the Integrator Block's State Port is restricted (and I have some more questions, see bel...

más de 4 años hace | 2 respuestas | 1

2

respuestas

Pregunta


How can I get the figure handle of a Scope window programmatically, given only the Scope block's full path name?
I've got the full path name of a Scope *block* as it is returned by find_system(...), e.g. 'myModel/Scope1'. In order to mani...

más de 7 años hace | 2 respuestas | 0

2

respuestas