I am using a CIC decimator block to downsample a high sample rate signal . the CIC decimator output is quite diffrent when i use it without unbuffer. but as for the FPGA apllication i need to unbuffer data the output is changed what could be the possible reason for this ? and how it could be resolved

Respuestas (1)

Bharath Venkataraman
Bharath Venkataraman el 13 de Jun. de 2022
Editada: Bharath Venkataraman el 13 de Jun. de 2022
Could you please provide a model that shows this behavior (you may want to try it using a fixed known input first)?
Are you sending in the input as a Mx1 array (sending it in as a 1xN array will have the block interpret it as multi-channel data).
  3 comentarios
Bharath Venkataraman
Bharath Venkataraman el 14 de Jun. de 2022
I want to make sure I have the problem understood correctly.
  1. You have a Simulink model with the CIC Decimator that simulates correctly.
  2. You generated HDL code and put it on the FPGA.
  3. On the FPGA, you are finding discrepancies.
If the above is true, please try using the FPGA in the Loop workflow. This will run the HDL code on the FPGA but get data in and out of Simulink. It is a good way to verify that the HDL code runs on the FPGA correctly.
On the FPGA, you can also use FPGA data capture to capture data going in and out of the filter.
muhammad ahmad
muhammad ahmad el 15 de Jun. de 2022
yup you have understood problem correctly. let me try the options you have asked for