Synchronous Machine pu Fundamental field winding bases
7 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Franco Huidobro Bandala
el 7 de Feb. de 2025
Editada: praguna manvi
el 15 de Abr. de 2025
Hi, everyone,
I have a question regarding the SPS block "Synchronous Machine pu fundamental". I opened the block (configured in continuous) to visualize the equations and write the model of the equations in per unit system and I found a gain called SM.N that multiplies the field voltage (Vfd).
Could you help me to understand the addition of this gain and could you share resources to understand the per-unit system that it is using.
I add a screenschot.

Thank you
0 comentarios
Respuesta aceptada
praguna manvi
el 13 de Feb. de 2025
Editada: praguna manvi
el 15 de Abr. de 2025
You can refer to the documentation for the "Synchronous Machine pu Fundamental," which mentions that the "Vf" input is normalized with respect to the nominal field voltage so that a 1 pu input produces a 1 pu stator voltage at no load. This is why there is a "Gain Block." Here is the link to the documentation:
Additionally, for more information on the "pu units system", refer to the following link:
Hope this helps!
0 comentarios
Más respuestas (0)
Ver también
Categorías
Más información sobre Electrical Block Libraries en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!