The Help file suggests that this should be possible. I am trying this with set(CompartmentName, 'Capacity', ParameterName) as the event function. The compartment, CompartmentName, has the appropriate units and is not ConstantCapacity. The parameter, ParameterName, is scoped to the model and has appropriate units. Verification fails as dimensional analysis cannot cope with set(). I can work around this in an adequate manner generating a SimBiology model object through M code but I wanted to know if this can be performed using the sbiodesktop interface.
0 comentarios
Respuesta aceptada
Arthur Goldsipe
el 1 de Dic. de 2015
Hi Bernard,
Yes, it's possible to change the capacity of a compartment using an event or assignment. To do this, set the corresponding event function or rule expression to a string of the form Variable = Expression.
But let me give you a simple example here. Let's say that you have a compartment named myCompartment and a parameter named myParameter, both of which have units of liter. Then, you could change this compartment's capacity to whatever value is associated with the parameter using an event function or rule of the form myCompartment = myParameter. And as you already discovered, you will need to make sure the compartment capacity is not marked as constant if you want to change it with a repeated assignment rule or event.
-Arthur