HDL Coder to / downto order
Mostrar comentarios más antiguos
Hi,
I'm using HDL Coder to generade VHDL code for a simulink block.
In the entity, the port order is generated as follow:
- for fixed-point variables, the output port is std_logic_vector(n downto 0)
- for boolean vector (Simulink Port dimension: [1 n]), the output port is std_logic_vector(0 to n)
Is it possible to change the order (to / downto), that all output ports have the same direction, and are not mixed for one entity?
My goal is to have downto for all outputs.
Respuesta aceptada
Más respuestas (1)
Kiran Kintali
el 8 de Sept. de 2023
Editada: Kiran Kintali
el 9 de En. de 2024
The control is now available starting R2023b release for boolean arrays.
Generate code for Boolean array with MSB-to-LSB convention
You can now generate code for an array of boolean data in most significant bit (MSB) to least significant bit (LSB) convention. For example, a subsystem with boolean input and output data, the generated VHDL code with the DOWNTO convention has this form:
ENTITY Subsystem IS
PORT ( In1 : IN std_logic_vector(4 DOWNTO 0); -- boolean [5]
Out1 : OUT std_logic_vector(4 DOWNTO 0) -- boolean [5] );
END Subsystem;
You can use this functionality for the VHDL®, Verilog®, and System Verilog target languages.
To revert to the old behavior you can use this option.
>> makehdl(<pathtodut>, 'BooleanVectorDownTo', 'off')
5 comentarios
Michael Felger
el 11 de Sept. de 2023
Eckhard Hennig
el 9 de En. de 2024
Is there an option in R2023b that allows the indexing order to be switched back to the previous behavior (0 to ...)? Generally, I'm happy about the change to the "downto" order, but I need to restore the previous behavior for compatibility with a proprietary add-on that relies on the "to" order.
Kiran Kintali
el 9 de En. de 2024
You can temporarily revert to the old behavior using 'BooleanVectorDownTo', 'off' option.
Till
el 16 de En. de 2026
@Kiran Kintali Is it possible to revert to the old behavior for one subsystems in a system composed of many subsystems which should majorily use the new behavior? If so, how would one set this up either script-based or from the Simulink GUI? Thanks in advance!
Kiran Kintali
el 16 de En. de 2026
Editada: Kiran Kintali
el 16 de En. de 2026
This is a model level option. It cannot be selectively disabled at a subsystem level. Please reach out to technical support for additional support.