Units for Time in Simulink
46 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Walter Franklin
el 3 de Dic. de 2020
Respondida: Giampiero Campa
el 29 de Oct. de 2021
For a continuous model what sets the time(scale?) in a simulink model?
As an example for openExample('simulink_general/sldemo_househeatExample') the scope x axis units are in hours. What sets that?
I know this is likely a trivial question, but my real aplication is to model transients in a physical thermal system without simscape. So far, the only way I have been able to match my hand calculated estimates using (with Q being the energy input each second) has been to use a descrete solver with a timestep of 1s but I know that I am going about things the wrong way.
Thank you for any guidence you can provide!
0 comentarios
Respuesta aceptada
Jonas
el 3 de Dic. de 2020
Editada: Jonas
el 3 de Dic. de 2020
Simulation time is always seconds.
In this particular model, they just adjusted the parameters (like heat power) such that 1 second corresponds with 1 hour. For the Heater, I see they multiply the parameter c with 3600. Also, they multiply the heat losses through the windows of the house with 3600. This way, every second the heat corresponding with one hour is generated. The x-axis can then be regarded as being in hours.
Otherwise the simulation would take way too long and would need to run 24*60*60 = 86400 seconds for it to finish just 24 hours. Now it finishes in just 24 seconds.
2 comentarios
Más respuestas (1)
Giampiero Campa
el 29 de Oct. de 2021
It is not seconds, it's an "unit of time" that you can relate to time units how you want, depending on your application. See also this: https://stackoverflow.com/questions/18650928/can-simulation-stop-time-in-simulink-be-compared-with-real-time
0 comentarios
Ver también
Categorías
Más información sobre General Applications en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!